HOME > Product > Vascular Model > Neuro Vascular(Large Models)

Neuro Vascular System XVII

Model:SJ001D-017
Material:Transparent silicone
Custom service:providing free design service&technical solutions
Payment:T/T
Lead time:7-15 days
Port: Ningbo,China
Shipping Methods:FedEx, DHL, EMS, UPS, TNT
For other types of models, pls visit our website or contact us.



Product Introduction:

This model extends from the femoral artery to the A2 segment of the anterior cerebral artery and the M2 segment of the middle cerebral artery. The neuro vessels are healthy without any lesion, additionally, the left and right coronary arteries in the cardiac thoracic section are normal. The abdominal section features a complex and realistic vascular structure. Through customized transparent connectors, the neuro, cardiac thoracic, and abdominal sections of this model can be detectable and replaceable, furthermore, those sections can be customized according to your diverse needs. In order to satisfy personalized needs, the Neuro section is equipped with two interchangeable small models, one featuring 5 aneurysms and 1 stenosis, while the other featuring 7 aneurysms and 1 AVM lesion. Moreover, for Cardiac thoracic section, we provide interchangeable small models with bifurcation and stenosis lesions.

 

Product usage:

1.Simulating intracranial aneurysm tamponade, intracranial thrombectomy, treatment for cerebral arteriovenous fistula and cerebral angiography.

2.Simulating coronary artery stenosis, bifurcations, CTO and other lesions, as well as training for percutaneous coronary intervention (PCI) procedures.

3.Applicable for development, testing, and validation of neuro and coronary interventional devices, including spring coils, stents, catheters, guidewires, microcatheters, micro guidewires, etc.

4. Applicable for demonstrations, training, and marketing of neuro, coronary, and abdominal interventional devices.

 

Customization options:

1.Neurovascular section: We can customize different numbers, sizes and locations of aneurysms, different locations of embolisms, stenosis , tortuosity, AVM and other lesions.

2.Aortic arch: It can be replaced with Type II arch, Type III arch, and anomalous arch (aortic arch malformation).

3.The model can be fixed inside a transparent acrylic tank to achieve a 3D effect.

4.We can customize model based on the data files provided in formats such as CT, CAD, STL, STP, STEP, etc.

Other products

©2024 Copyright ©Trandomed 3D Inc. All Rights Reserved.  浙ICP备17017401号